Saunders & Weeks (Bristol) Ltd Vacuum & Temperature Instrumentation - click here for text version.
   
  Tel: (+44) 0117 9557142 Fax: (+44) 0117 9556064
  HOME
  GAUGES
 
 
 
 
 
 
 
 
 
 
  TANK CONTENTS
 
  THERMOMETERS
 
 
  EXTRA
 
 
  CONTACT
  CONTACT US / REQUEST A CATALOGUE
 
 
 
NOT SURE WHICH
INSTRUMENT YOU NEED?

CLICK HERE OR
CALL US NOW
ON 0117 9557142
FOR EXPERT HELP
AND ADVICE
 
 
 
MANUFACTURERS + REPAIR & RECALIBRATION
Pressure, vaccum, temperature instrumentation
 
GAUGES>>TANK CONTENTS
 

28RBP & 28RD - Remote Indicating Tank Contents Gauge with either INTERNAL or EXTERNAL Transmitter

 
Application
  • Used mostly for storage tanks containing fuel oil, water or slurries.
  • The transmitter is fitted at any suitable position as near to the base of the tank as possible, thus indicating the contents of liquid above the transmitter position.
  • Indicators are graduated in fractions or 0-100%, litres, gallons, tons or m3.
  • 100mm or 160mm dial size.
 
Remote Indicating Tank Contents Gauge
INTERNAL or EXTERNAL Transmitter
 

Specifications Indicator

Mounting: Surface as photo or Flush Panel
Accuracy: 1%
Case & Bezel: 304 St. St Bayonet locking bezel
Measuring Element: Phosphor Bronze
Movement: Brass
Dial: White Aluminium with black markings
Pointer: Black Oxidised Aluminium
Window: Glass/Clear Acrylic
Gasket Seal: Food Quality Rubber
 

Transmitter

Body: ‘B’ type external – Polypropylene
‘D’ type internal - Brass
Connection: ‘B’ type - Brass 3/4”bsp Female nut & tail supplied with 3/4”bsp self-closing valve
‘D’ type – 1” BSP bush
Sensing Element: Nitrile
Capillary: ‘B’ type – 2mm o.d. copper microbore tube with 9mm o.d. solid black PVC protection sheath.
‘D’ type – as ‘B’ type but internal is St.St. armour covered copper
Alternative protection
Sheath:
 St St armoured through-out
 
General Description  

The Instrument operates on the hydrostatic principal, where pressure due to head of liquid is sensed by the Transmitter Head and transmitted via capillary tube to the indicator giving a continuous level reading.

The gauge is suitable for installation on any shape or size of storage vessel that is freely vented to atmosphere.

A 3/4”bsp male/male self closing valve is supplied with ‘B’ type transmitter to allow removal of the transmitter without loss of liquid.

 
 
 
   
Saunders & Weeks (Bristol) Ltd, 265-267 Church Road, Redfield, Bristol BS5 9HU, United Kingdom